[C-WL-LC60] Wiring Instructions

[C-WL-LC60] Wiring Instructions



Warning
  1. Turn off the power.
    1. To avoid electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation and maintenance.
    2. Be aware that even if the circuit breaker is off, some voltage may remain in the wires — before proceeding with the installation, be sure no voltage is present in the wiring.
    3. Take extra precautions to avoid accidentally turning the device on during installation.
The WLED controller can support a total of three output channels.
The output terminal connections "G D V" correspond to the "GND DATA VCC" pins of the digital LED strips.
Among them, D refers to the default output group for GPIO16, so please prioritize using this group.
The other group, D for GPIO2, can only be used after configuration in the APP.
IO33 is an extended GPIO signal port that can be customized for use.