[C-ZB-SM30-2G] Hardware & Switching FAQs

[C-ZB-SM30-2G] Hardware & Switching FAQs


Button and LED Indicator Operation
No.OperationKeyDescription
1.1Short press (once)K1Switches L1 load ON/OFF
K2Switches L2 load ON/OFF
1.2Short press (three times)K1Enables Find and Bind mode for Endpoint 1, or removes a paired Zigbee Green Power remote. The LED indicator flashes three times in a 3-second cycle.
K2Enables Find and Bind mode for Endpoint 2, or removes a paired Zigbee Green Power remote. The LED indicator flashes four times in a 3-second cycle.
1.3Short press (four times)K1Enables TouchLink commissioning for Endpoint 1. The LED indicator flashes slowly. Upon successful TouchLink commissioning, the LED indicator flashes rapidly for 3 seconds.
K2Enables TouchLink commissioning for Endpoint 2. The LED indicator flashes slowly. Upon successful TouchLink commissioning, the LED indicator flashes rapidly for 3 seconds.
1.4Short press (five times)K1Performs a factory reset and enters network pairing mode. This mode remains active for 180 seconds or until the device is successfully added to a Zigbee network. The LED indicator flashes rapidly during this period.
How does the device handle Overload or Overheat protection?
Overload Protection: If the device experiences an overload, the LED will flash slowly (every 0.5s) and a notification is sent to the gateway every minute. The output will remain disabled until the alarm is cleared or the device is restarted.

Overheat Protection: If the power board temperature exceeds 95 °C, the output will shut down and a warning will be sent to the Zigbee gateway. Normal operation resumes automatically once the device is restarted and the temperature falls below 95 °C.