[C302-WF] Wiring Instructions
- Turn off the power
- To avoid electrical shock and/or equipment damage, disconnect ectrical power at the main fuse or circuit breaker before installation and maintenance.
- Be aware that even if the circuit breaker is off, some voltage may remain in the wires — before proceeding with the installation, be sure no voltage is present in the wiring.
- Unscrew the existing switch/dimmer from the wall, and before removing the wires note where the wires are connected. Taking a photo is also useful for comparison.
- Connect the device according to the diagrams shown below for either a 1-way or 2-way/multiway system.
When wiring a 2-way/multiway system only 1 dimmer can be used in the circuit. All other switches must be (non-smart) push/retractive switches, with only one direction i.e. bottom OR top only. On/off toggle switches are not supported. Push/retractive switches should be press to make.
Related Articles
[C-WF-SSFS] Smart Switch Fused Spur - Getting Started
Manual & Documentation Download the Instruction Manual here: C-WF-SSFS Instruction Manual Installation Instructions To install your smart switch, please remove the screws to take off the front, then the back can be screwed onto the wall. Turn off the ...
[C302-WF] Wi-Fi Rotary Dimmer - Getting Started
Manual & Documentation Download the official PDF instruction manual for detailed specifications and safety notes. Download Instruction PDF Wiring Guide Access wiring diagrams and switch configuration walkthroughs. View Wiring Instructions ...
[C302-WF] Retractive Switch Notes
Requirements Retractive switches should be 2 position/way switches (i.e. bottom or top only, no middle, no 2 way/position and off) Retractive switches should also be press to make, not press to break. Some retractive switches have one terminal for ...
[C-WL-LC60] Retractive Switch Notes
Requirements Retractive switches should be 2 position/way switches (i.e. bottom or top only, no middle, no 2 way/position and off) Retractive switches should also be press to make, not press to break. Some retractive switches have one terminal for ...
[C-ZB-RD1/C-ZB-RD1P] Wiring instructions
Turn off the power. To avoid electric shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation and maintenance. Be aware that even if the circuit breaker is off, some voltage may remain in the ...