[C130-S] Wiring Instructions
If you have any concerns about wiring this yourself, please consult a qualified electrician.
- Turn off the power
- To avoid electrical shock and/or equipment damage, disconnect electrical power at the main fuse or circuit breaker before installation and maintenance.
- Be aware that even if the circuit breaker is off, some voltage may remain in the wires — before proceeding with the installation, be sure no voltage is present in the wiring.
- Take extra precautions to avoid accidentally turning the device on during installation
- This is normally installed just before the first light fitting in the circuit, but can also be installed just after a switch, if you have access to a neutral wire, and switched live wire.
- Connect the device according to the diagrams shown below.
General Wiring
Before the first light fitting
After the light switch
C-ZB-RD1/RD1P Wiring
Installing the bypass at the switch when a neutral wire is available
No Load Wiring for REM Mode
It is possible to the wire the RD1-Pro using
Live and Neutral wires, without a wired lamp Load.